{"id":1985,"date":"2017-05-12T08:22:03","date_gmt":"2017-05-12T08:22:03","guid":{"rendered":"http:\/\/axiomed.ro\/shop\/autolyser-450\/"},"modified":"2021-12-11T18:43:41","modified_gmt":"2021-12-11T18:43:41","slug":"autolyser-450","status":"publish","type":"product","link":"https:\/\/axiomed.ro\/en\/shop\/autolyser-450\/","title":{"rendered":"AUTOLYSER 450"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p>General characteristics<\/p>\n<p>Working speed: 690 tests \/ hour with ISE mode; 450 tests \/ hour without ISE module;<br \/>\nThe ISE module (Na, K, Cl, Li) is optional &#8211; the analyzer is available in ISE mode or ISE mode;<br \/>\nOperating mode: Sequential;<br \/>\nWorking Modes: Routine, Batch, Emergency (STAT), Profiles;<br \/>\nMemory for up to 500 tests;<br \/>\nSamples: serum, urine, plasma, CSF;<br \/>\nPre-dilution for samples;<br \/>\nPre-calibration pre-dilution;<br \/>\nReactive Rotor &#8211; Cooling;<br \/>\nRotor calibrators and controls &#8211; with cooling;<br \/>\nWashing station for reaction vessels;<br \/>\n13-channel (340-800 nm) photometer &#8211; &#8222;solid state photometer&#8221;;<br \/>\nDurable ceramic dilator &#8211; &#8222;Long life ceramic dilutor&#8221;;<br \/>\nClot sensor;<br \/>\nImpact sensor;<br \/>\nQuality Control Program &#8211; QC;<br \/>\nPatient archive;<br \/>\nOperation via an external computer (delivered with the analyzer);<br \/>\nSpecial glass optic reaction tubes with long service life (not replaceable, non-consumable);<br \/>\nInternal barcode reader for identification of samples and reagents;<br \/>\nLIS bidirectional communication system &#8211; for connection to laboratory software;<br \/>\nTanks for washing water and waste water;<br \/>\nStandard Dialab Reagents (standard packaging) or Dialab Type &#8222;System Packs&#8221; Reagents can be used.<br \/>\nMethods<\/p>\n<p>&#8222;End Point&#8221; (with or without sample blank or reagents);<br \/>\n&#8222;Fixed time&#8221;;<br \/>\nkinetic;<br \/>\nEasy reading.<br \/>\nTypes of calibration<\/p>\n<p>With Best fit factor<br \/>\nLinear In Points (Multipoint)<br \/>\nLog-logit calibration curve 4<br \/>\nCubic spline log-log 5<br \/>\nPolinomial Semi-log<br \/>\nReagents \/ Samples \/ Calibrators and Controls \/ Reaction Covers<\/p>\n<p>Reactive Rotor: 80 Cooling Positions;<br \/>\nRotor sample: 100 positions;<br \/>\nRotor calibrators and controls: 26 positions with cooling;<br \/>\nReactor Rotor: 84 special glass optics with heating system;<br \/>\nSample volume: 1.5 \u03bcL &#8211; 100 \u03bcL;<br \/>\nReaction volume: 180 \u03bcL &#8211; 400 \u03bcL;<br \/>\nTemperatures at which thermostats of the reaction vessels can be made: OFF \/ 30 \u00b0 C \/ 32 \u00b0 C \/ 37 \u00b0 C +\/- 0.2 \u00b0 C (Peltier system controlled).<br \/>\nphotometer<\/p>\n<p>13-channel &#8222;Solid state photometer&#8221; + 1 reference channel;<br \/>\nWavelengths: 340, 380, 405, 436, 480, 510, 546, 578, 600, 660, 700, 740, 800 nm;<br \/>\nAbsorbance range: 0.000 &#8211; 3.000 Abs;<br \/>\nSensitivity: +\/- 0.001 Abs;<br \/>\nAccuracy: +\/- 1% from 0 to 2000 OD;<br \/>\nTungsten halogen lamp with reflector;<br \/>\nLamp lifetime &#8211; about 2000 hours.<br \/>\nPipette arms \/ Dilator<\/p>\n<p>1 x pipetting arm for samples;<br \/>\n2 x pipetting arms for reagents;<br \/>\n3 x long life ceramic dilators (&#8222;Long life ceramic&#8221;);<br \/>\nAccuracy of diluents: +\/- 0.1%;<br \/>\nResolution of diluents: +\/- 0.1\u03bcL for serum samples; +\/- 1.0 \u03bcL for reagents.<br \/>\nWater consumption<\/p>\n<p>9.5 ml \/ test<br \/>\nInterface<\/p>\n<p>USB port;<br \/>\nPort RS232;<br \/>\nLAN port.<br \/>\nElectrical Requirements, Dimensions and Weight<\/p>\n<p>100\/240 VAC, 50 &#8211; 60 Hz, 400 Watt;<br \/>\nU.P.S .: 1500 Watt;<br \/>\nNet weight: 162 kg;<br \/>\nGross weight: 237 kg;<br \/>\nDimensions: 1150 x 1150 x 720 mm.<br \/>\nCE conformity marking; Quality standards: EN ISO 9001, EN ISO 13485.<\/p>\n<p>The analyzer can be purchased without ISE or ISE mode.<\/p>\n<p>The analyzer comes with an external computer and printer.<\/p>\n<p>Warranty: 2 years from date of commissioning.<\/p>","protected":false},"excerpt":{"rendered":"<p>AUTOMATIC ANALYZER BIOCHEMISTRY AND IMMUNOTURBIDIMETRY \u00a0690 tests \/ hour &#8211; production: DIALAB, Austria<\/p>","protected":false},"featured_media":1987,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1396],"product_tag":[],"class_list":{"0":"post-1985","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-fara-categorie","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/product\/1985","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/comments?post=1985"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/media\/1987"}],"wp:attachment":[{"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/media?parent=1985"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/product_brand?post=1985"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/product_cat?post=1985"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/axiomed.ro\/en\/wp-json\/wp\/v2\/product_tag?post=1985"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}